NOR-RAY-VAC CONTINUOUS
RADIANT TUBE SYSTEM
INSTALLATION INSTRUCTION MANUAL
WARNINGS
AmbiRad equipment must be installed and maintained in accordance with the relevant
provisions of the Gas Safety (Installations and Use) Regulations 1998 for gas fired products.
Due account should also be taken of any obligations arising from the Health and Safety at
Works Act 1974 or relevant codes of practice. In addition the installation must be carried out
in accordance with the current IEE wiring regulations (BS 7671), BS 6896 (Industrial &
Commercial) and any other relevant British Standards and Codes of Practice by a qualified
installer. All external wiring MUST comply with the current IEE wiring regulations.
Part No. 700052
Instruction Manual
AmbiRad Limited, Fens Pool Avenue, Brierley Hill, West Midlands, DY5 1QA
INDEX Section
Installation Requirements ------------------------------------------------ 1
User and Operating Instructions ---------------------------------------- 2
Vue de la page 0
1 2 3 4 5 6 ... 27 28

Résumé du contenu

Page 1 - NOR-RAY-VAC CONTINUOUS

NOR-RAY-VAC CONTINUOUS RADIANT TUBE SYSTEM INSTALLATION INSTRUCTION MANUAL WARNINGS AmbiRad equipment must be installed and maintained in accordance

Page 2 - Document Index

10 1.6.1 NRV LR system - Typical External Diagram In-line Burner In-line Burner In-line Burner In-line Burner End Vent Burner Fused Spur Fused Spur

Page 3 - Introduction

11 MAINGREYREDREDFLAME SENSORIGNITOR8791110121324BLACKPURPLEREDLAMPSONMAINSGRN/YELBROWNSOLENOIDGREEN/YELLOWSWITCHN.O.N.C.C.NLONBURNERBLUEVACUUMBROWNV

Page 4 - 1.3 Heater Suspension

12 Figure 4.e. LR internal wiring diagram - End Vent Burner c/w N/O or N/C volt free Lockout contacts Figure 4.f. LR internal wiring diagram - In-lin

Page 5

13 MAINGREYREDREDFLAME SENSORIGNITOR8791110121324BLACKPURPLEREDLAMPSONMAINSGRN/YELBROWNSOLENOIDGREEN/YELLOWSWITCHN.O.N.C.C.NLONBURNERBLUEVACUUMBROWNV

Page 6

14 Figure 4.j. NRV Inverter Internal Wiring Diagram for B80, B160 and B300 three phase fans Figure 4.k. NRV Local Relay Unit Internal Wiring Diagram

Page 7

15 THE LOCAL RELAY UNIT houses an inverter. Thisconverts the 230V single-phase input into athree-phase 230V output. The inverter provides asoft start

Page 8

16 Supply via Isolator230V 50Hz 1 PhaBurnersZone ADrawing No. : 900289 R8Supply to inlineburners(HEAT 1 OUTPUT)(LIVE)(NEUTRAL)NOTES:REMOTE SWITCH INP

Page 9

17 Figure 4.n. NRV Schematic interconnecting wiring. B80, B160 and B300 three phase fans controlled by SmartCom3 via single phase Inverter panel. Zo

Page 10 - From ‘Power out’

18 THE LOCAL RELAY UNIT houses an inverter. Thisconverts the 230V single-phase input into athree-phase 230V output. The inverter provides asoft start

Page 11 - 1.6.2 Wiring Details

19 1.7 Ventilation Requirements Nor-Ray-Vac heaters are installed as flued appliances in accordance with the relevant national requirements in

Page 12

Document Index. 1 Installation Requirements 1.1 Health & Safety 1.2 Burner Model Definitions 1.3 Heater Suspension 1.4 Clearance to Combustible

Page 13

20 1.8.3 Ducted Air Inlet Considerations. Heat resistant flexible tube is connected to the burner assembly ducted air adaptor and the EVM ducted air

Page 14 - TERMINAL RAIL

21 Fan Size B80 B160 B300 BH300 A (crs) 216 276 286 324 B 595 595 625 704 C 305 308 330 352 D 580 555 575 650 E (Ø) 150 152 152 152 F 5

Page 15 - Singlezone

22 Burner Type 12LR 18LR 24LR 32LR 38LR 46LR Burner Details G20 Natural Gas Gas Category II Heat input (Gross) kW 12 18 24 32 38 46 Gas

Page 16

23 Burner Type 12LR 18LR 24LR 32LR 38LR 46LR Burner Details G30 Butane Gas Gas Category III Heat input (Gross) kW 12 18 24 32 38 46 Gas

Page 17

24 Table 5. Heater Details 12LR 18LR 24LR 32LR 38LR 46LR Min distance between burners m 5.2 7.4 9.4 14 18 23 Max distance between burn

Page 18

25 Table 10. Local Relay Unit Fan Size B80 B160 B300 BH300 LRU part number 900274 900088 900089 900282 Inverter type kW 1.5 1.5 2.2 n/a

Page 20

Notes.

Page 21

2. User & Operating Instructions. Document reference number GB/NRV/193I/0314 2.1 To Start the Heater 1. Ensure that gas supply is turned on at

Page 22 - G20 Natural Gas

3 1. Installation Requirements. Isolate any electrical supply to the heat-er and controller before proceeding. For your own safety we recommend the u

Page 23 - G31 Propane Gas

4 1.3 Heater Suspension 1.3.1 First considerations • Clearances from combustibles must be maintained. (See figure 2) • For ease of servicing the

Page 24

5 Figure 1.b Clearance for servicing - distances to walls and obstacles above. Figure 1.c Clearance for servicing - distances to obstacles above. G G

Page 25 - ∆ ∆ ∆

6 1.4 Clearance to Combustibles. The minimum clearances to combustible materials are given in table 2 below. These minimum distances MUST be adhere

Page 26

7 Take care when making a gas connection to the heater not to apply excessive turning force to the internal controls. A flexible hose is installed t

Page 27

8 fig.e 400 +/- 50mm 50 +/- 20mm Burner fig.c Depending on the specific installation, the flexible gas hose may be routed to the gas cock at any of

Page 28

9 In-line Burner End Vent Burner ‘Power out’ from End Vent Burner to In-line Burner(s) Fused Spur Fused Spur 230V 50Hz Switched Supply from Control S